Sign In | Join Free | My fazendomedia.com
China ASLi (CHINA) TEST EQUIPMENT CO., LTD logo
ASLi (CHINA) TEST EQUIPMENT CO., LTD
AI SI Li (CHINA) TEST EQUIPMENT CO., LTD High Quality Assurance , Good After-sales Coexistence !
Active Member

10 Years

Home > Walk In Stability Chamber >

Walk in Stability Chamber with 20%~98 R.H.

ASLi (CHINA) TEST EQUIPMENT CO., LTD
Contact Now

Walk in Stability Chamber with 20%~98 R.H.

Brand Name : ASLi

Model Number : THR

Place of Origin : Dongguan City , Guangdong Province ,China

MOQ : 1 Set

Price : Negotiation

Payment Terms : T/T, Western Union

Supply Ability : 20 Set Per month

Delivery Time : 40-45 work days

Packaging Details : Export Standard Plywood Case

Certification : CE

Brand : ASLi

Model : THR

Integral style : -70~200 Deg C / 20%~98%R.H

Detachable style : -70~120 Deg C ; 20%~98%R.H When -70 to 65 Deg C

internal Dimesion : customers designated space size and design

Temp.Rising rate : 0.1~3.0°C/min

Temp.Falling rate : 0.1~1.0°C/min

Cooling System : water cooling

Power : AC 380 V,50/60HZ ,3ph 5 Lines

Compressor : French Tecumseh Brand, Germany Brand

Contact Now

-70 Deg C Tempearture Humidity Testing Walk-in Stability Chamber with 20%~98 R.H.

Equipment Summary:

ASLi Walk-in Stability Chamber is consist of Control Panel, electrical panels, moisturizing plate blower, heater, humidifier, freezer. It provides a large spare to test the temperature and humidity for large-scale parts, semi-finished products, it applied to test products that large-scale or the quantity more, such as: computer terminals, vehicle parts.

Corresponding Standard:

1. GB11158 Technical conditions for high-temperature testing room

2. GB10589-89 Technical conditions for low-temperature testing room

3. GB/T10586-89 technical conditions for humidity testing room

4. GB/T2423.1-2001 testing methods for low-temperature

5. GB/T2423.2-2001 testing methods for high-temperature

6. GB/T2423.3-93 technical conditions for humidity testing room

7. GB/T2423.4-93 testing method for alternating hot and humid

8. IEC60068-2-1.1990 testing methods for low-temperature

9. IEC60068-2-2.1974 testing methods for high-temperature

10. GJB150.3 High-temperature test

11. GJB150.4 Low-temperature test

12. GJB150.9 muggy test

13. GB/T2423.22 temperature test

Applicable Industry:

used in defense industry, aerospace industry, automation components, automotive parts, electrical and electronic parts, plastics, chemical, pharmaceutical industries and related products

Walk in stability environmental rooms technical parameters:

Model

TH-80

(A~F)

TH-150

(A~F)

TH-225

(A~F)

TH-408

(A~F)

TH-800

(A~F)

TH-1000

(A~F)

Internal Dimension WxHxD (mm)

400x500x

400

500x600x

500

600x750x

500

600x850x

800

1000x1000x

800

1000x1000x

1000

External Dimension WxHxD (mm)

950x1650

x950

1050x1750

x1050

1200x1900

x1150

1200x1950

x1350

1600x2000

x1450

1600x2100

x1450

Temperature Range

Low Temperature(A:25°C B:0°C C:-20°C D:-40°C E:-60°C F:-70°C)

High Temperature 150°C

Humidity Range

20%~98%R.H.(10%-98% R.H. / 5%-98% R.H.,is optional , need Dehumidifier)

Distribution Uniformity

of temperature and humidity

±2.0°C; ±3.0% R.H.

Control Accuracy

of Temp. and Humi.

±0.5°C; ±2.5% R.H.

Temperature

Humidity Control

Chart

Walk in Stability Chamber with 20%~98 R.H.

Temperature Rising

/Falling Velocity

Rising approx. 0.1~3.0°C/min;

Falling approx. 0.1~1.5°C/min; ( Falling >1.5°C/min is optional)

Inner and Outer

Material

Interior is SUS 304# stainless steel, exterior is stainless steel or see cold-rolled steel with paint coated.

Insulation Material

Resistant to high temperature, high density, formate chlorine, ethyl acetum foam insulation materials

Cooling System

Wind cooledor water cooled; single segment compressor for -40°C, double segment compressor for -70°C

Protection Devices

Fuse-free switch, overloading protection switch for compressor, high and low voltage coolant protection switch, over-humidity and over-temperature protection switch, fuses, fault warning system, water short storage warning protection

Optional Accessories

Inner door with operation hole , Recorder, Water Purifier, Dehumidifier

Compressor

French Tecumseh Brand, Germany Bizer Brand

Power

AC220V 50/60HZ , AC380V 50/60HZ

Weight (Kg)

150

180

250

320

400

450

Walk in Stability Chamber with 20%~98 R.H.

Walk in Stability Chamber with 20%~98 R.H.

Walk in Stability Chamber with 20%~98 R.H.

Ms.Joanna Wen
ASLi (CHINA) TEST EQUIPMENT CO., LTD
Walk in Stability Chamber with 20%~98 R.H.Company Add.:Building C,JinHui Industrial Park, LiXin town,East City district 523125,DongGuan City,China
Tel.:0086-769-23164266
Cell: 0086-13826932967
Fax:0086-769-22851784
Website: http://www.asLitesting.com

Product Tags:

environmental test chamber

      

walk in environmental chamber

      
Best Walk in Stability Chamber with 20%~98 R.H. wholesale

Walk in Stability Chamber with 20%~98 R.H. Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ASLi (CHINA) TEST EQUIPMENT CO., LTD
*Subject:
*Message: